UGET 3 +

particulate filters

DESCRIPTION
Exhaust gas purification is an ever evolving technology and Bersy are continually improving their range of exhaust gas purification systems in order to offer the most advanced, long lasting and reliable solutions.
After many years of research and development into improving exhaust emissions, Bersy now presents this innovative exhaust gas filtration system.
The UGET 3 + is a dry particulate filter system, capable of reducing particulate matter by over 99%.
The environmental and health advantages are clear, enabling customers to meet the very stringent regulations laid down by Government Health and Safety executives.
Therefore the UGET 3+ filter has been BAFU (SWISS) & EST ENERGY SAVING TRUST (UK) certified as well as TRGS 554 compliant. The UGET3+ filter is listed as being suitable for installation to meet MSHA Part 72 Diesel Particulate Matter (DPM) regulatory requirements.

OPERATING PRINCIPLE
Very fine unburnt carbon particles are responsible for the typical black smoke emitted from a diesel engine exhaust. They are the main cause of many respiratory illnesses and also have a damaging effect on the environment.
These negative effects are compounded when diesel vehicles are used in confined spaces or in close proximity to human beings (i.e. tunnels, mines, quarries or in factories and warehouses).


The UGET 3 + filter housing is made of stainless steel and encompasses a heat shield for protection against burns. The filter cartridge resists up to 300°C for 4 hours of use and 260°C continuously.
The texture weave of the special fibres retains carbon particles as small as 20nm.
The filter system is fitted in addition to the existing exhaust system and the fibrous material of the filter element traps the carbon particles, retaining them in the filter allowing the remaining exhaust gases to pass through.
UGET 3 + filters are available in various standard sizes and are supplied complete with cartridge(s) ready for immediate use. As well as standard models shown here, Bersy can produce units suitable for even larger engines to suit customers’ individual needs.

FITTING INSTRUCTIONS
Bersy recommend that the UGET 3 + filter is fitted as far away as possible from the engine to avoid any problems with the filter overheating.

The filter housing should be fitted to the vehicles frame or body with fixing brackets and connected with a piece of flexible pipe, using the counter flanges supplied, to the existing exhaust outlet.

It is advised to fit the UGET 3 + filter system after the silencer. Fitting the pressure control kit is straightforward and is compulsory in some European countries.


MAINTENANCE
The filter does not require any scheduled maintenance.
At the end of the filter cartridge life, the back plate and cartridge are removed and replaced with a new one.
Used cartridges are not classed as hazardous waste, but must be disposed of as special waste.
Bersy suggest verifying local regulations for the disposal of used cartridges.

FILTER LIFE
The life of the filter element depends on the condition and maintenance of the engine.

PRESSURE CONTROL KIT
In order to check the efficiency of the system, an additional control system is available separately to verify the back pressure created by the filter.
Through a LED, the pressure control kit shows the operator the filter is working correctly or if any necessary maintenance is required.
Also available is the ECU BYBOX, an advanced control system to monitor temperature and pressure, storing the related data values for evaluation later.


BACK PRESSURE TESTS
Back Pressure tests have been carried out to record the pressures caused by the filter at different stages of its life. The graph shows average values observed.

CODEMODELPOWERAØBØCD
20000100 D 20 up to KW 12 356 234 50 510
20000101 D 40 up to KW 22 606 234 50 650
20000102 D 80 up to KW 45 620 296 80 650
20000103 D 125 up to KW 68 620 366 80 960
20000104 D 200 up to KW 113 872 464 101 885
20000105 D 300 up to KW 170 1096 464 114 885
CODEMODELPOWERABØCDE
20000106 D 400 up to KW 227 1081 464 139 850 885
20000107 D 600 up to KW 340 1305 464 139 850 885

CODEMODELPOWERABØCØDE
20000108 D 900 up to KW 510 1514 900 168 168 1080
20000109 D 1200 up to KW 680 1514 950 219 219 1130
20000110 D 1500 up to KW 850 1614 1200 219 219 1440
20000111 D 1800 up to KW 1020 1614 1250 273 273 1480
20000112 D 2100 up to KW 1190 1614 1250 273 273 1480
20000113 D 2400 up to KW 1360 1614 1350 324 324 1550
20000114 D 2700 up to KW 1530 1624 1700 356 356 2000
20000115 D 3000 up to KW 1700 1624 1800 356 356 2100
CODEMODELPOWERØAØBC
20000064 D 40 up to KW 22 265 80 980
20000090 D 80 up to KW 45 290 80 980
Supplied with counter flange, gasket, bolts and nuts.

Disclaimer: the information and dimensions shown are correct at time of press. Due to technological advancements are subject to change without notice.